Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Type of study
Language
Year range
1.
Bol. latinoam. Caribe plantas med. aromát ; 20(4): 406-415, jul. 2021. ilus, tab
Article in English | LILACS | ID: biblio-1352429

ABSTRACT

Alzheimer's disease (AD) is an age-related neurodegenerative disorder. Sever cognitive and memory impairments, huge increase in the prevalence of the disease, and lacking definite cure have absorbed worldwide efforts to develop therapeutic approaches. Since many drugs have failed in the clinical trials due to multifactorial nature of AD, symptomatic treatments are still in the center attention and now, nootropic medicinal plants have been found as versatile ameliorators to reverse memory disorders. In this work, anti-Alzheimer's activity of aqueous extract of areca nuts (Areca catechu L.) was investigated via in vitro and in vivo studies. It depicted good amyloid ß (Aß) aggregation inhibitory activity, 82% at 100 µg/mL. In addition, it inhibited beta-secretase 1 (BACE1) with IC50 value of 19.03 µg/mL. Evaluation of neuroprotectivity of the aqueous extract of the plant against H2O2-induced cell death in PC12 neurons revealed 84.5% protection at 1 µg/mL. It should be noted that according to our results obtained from Morris Water Maze (MWM) test, the extract reversed scopolamine-induced memory deficit in rats at concentrations of 1.5 and 3 mg/kg.


La enfermedad de Alzheimer (EA) es un trastorno neurodegenerativo relacionado con la edad. Los severos deterioros cognitivos y de la memoria, el enorme aumento de la prevalencia de la enfermedad y la falta de una cura definitiva han absorbido los esfuerzos mundiales para desarrollar enfoques terapéuticos. Dado que muchos fármacos han fallado en los ensayos clínicos debido a la naturaleza multifactorial de la EA, los tratamientos sintomáticos siguen siendo el centro de atención y ahora, las plantas medicinales nootrópicas se han encontrado como mejoradores versátiles para revertir los trastornos de la memoria. En este trabajo, se investigó la actividad anti-Alzheimer del extracto acuoso de nueces de areca (Areca catechu L.) mediante estudios in vitro e in vivo. Representaba una buena actividad inhibidora de la agregación de amiloide ß (Aß), 82% a 100 µg/mL. Además, inhibió la beta-secretasa 1 (BACE1) con un valor de CI50 de 19,03 µg/mL. La evaluación de la neuroprotección del extracto acuoso de la planta contra la muerte celular inducida por H2O2 en neuronas PC12 reveló una protección del 84,5% a 1 µg/mL. Cabe señalar que, de acuerdo con nuestros resultados obtenidos de la prueba Morris Water Maze (MWM), el extracto revirtió el déficit de memoria inducido por escopolamina en ratas a concentraciones de 1,5 y 3 mg/kg.


Subject(s)
Animals , Rats , Areca/chemistry , Plant Extracts/administration & dosage , Alzheimer Disease/drug therapy , beta-Amylase/antagonists & inhibitors , Amyloid beta-Peptides/drug effects , Aspartic Acid Endopeptidases/antagonists & inhibitors , Aspartic Acid Endopeptidases/drug effects , Neuroprotective Agents , Amyloid Precursor Protein Secretases/antagonists & inhibitors , Amyloid Precursor Protein Secretases/drug effects , Alzheimer Disease/enzymology , Alzheimer Disease/prevention & control , Morris Water Maze Test , Medicine, Traditional
2.
Dental press j. orthod. (Impr.) ; 20(1): 59-65, Jan-Feb/2015. tab, graf
Article in English | LILACS | ID: lil-741448

ABSTRACT

OBJECTIVE: The aim of the present study was to assess the diagnostic value of a laser scanner developed to determine the coordinates of clinical bracket points and to compare with the results of a coordinate measuring machine (CMM). METHODS: This diagnostic experimental study was conducted on maxillary and mandibular orthodontic study casts of 18 adults with normal Class I occlusion. First, the coordinates of the bracket points were measured on all casts by a CMM. Then, the three-dimensional coordinates (X, Y, Z) of the bracket points were measured on the same casts by a 3D laser scanner designed at Shahid Beheshti University, Tehran, Iran. The validity and reliability of each system were assessed by means of intraclass correlation coefficient (ICC) and Dahlberg's formula. RESULTS: The difference between the mean dimension and the actual value for the CMM was 0.0066 mm. (95% CI: 69.98340, 69.99140). The mean difference for the laser scanner was 0.107 ± 0.133 mm (95% CI: -0.002, 0.24). In each method, differences were not significant. The ICC comparing the two methods was 0.998 for the X coordinate, and 0.996 for the Y coordinate; the mean difference for coordinates recorded in the entire arch and for each tooth was 0.616 mm. CONCLUSION: The accuracy of clinical bracket point coordinates measured by the laser scanner was equal to that of CMM. The mean difference in measurements was within the range of operator errors. .


OBJETIVO: o objetivo do presente estudo foi avaliar o valor diagnóstico de um scanner a laser desenvolvido para determinar as coordenadas dos pontos de colagem de braquetes, comparando seus resultados aos resultados obtidos com uma máquina de medição coordenada (MMC). MÉTODOS: esse estudo experimental diagnóstico foi conduzido com modelos ortodônticos obtidos a partir da arcada superior de 18 pacientes adultos, com oclusão normal de Classe I. Inicialmente, as coordenadas dos pontos de colagem de braquetes de todos os modelos foram mensuradas por uma MMC. Em seguida, as coordenadas tridimensionais (X, Y, Z) dos pontos foram mensuradas nos mesmos modelos por um scanner a laser 3D, desenvolvido na Universidade de Shahid Beheshti. A eficácia e confiabilidade dos dois sistemas foram avaliadas pelo Coeficiente de Correlação Intraclasse (CCI) e pela fórmula de Dahlberg. RESULTADOS: a diferença entre a média da dimensão mensurada pela MMC e o valor real obtido foi de 0,0066mm (IC 95%: 69,98340 - 69,99140). A diferença média para o scanner a laser foi de 0,107 ± 0,133 (95% IC: -0,002 - 0,24). Em cada método, as diferenças não foram significativas. Ao comparar os dois métodos, o CCI gerou um valor de 0,998 para a coordenada X e de 0,996 para a coordenada Y. A diferença média para as coordenadas registradas em cada dente da arcada foi de 0,616mm. CONCLUSÃO: a precisão das coordenadas do ponto de colagem dos braquetes foi a mesma no scanner a laser e na MMC. A diferença média entre as medições manteve-se dentro dos limites de erros operacionais. .


Subject(s)
Animals , Humans , Alzheimer Disease/genetics , Amyloid Precursor Protein Secretases/genetics , Hidradenitis Suppurativa/genetics , Presenilin-1/genetics , Alanine/analogs & derivatives , Alanine/pharmacology , Alzheimer Disease/enzymology , Amyloid Precursor Protein Secretases/antagonists & inhibitors , Azepines/pharmacology , Hidradenitis Suppurativa/enzymology , Mutation, Missense
SELECTION OF CITATIONS
SEARCH DETAIL